Access a comprehensive, professionally formatted Material Test Certificate according to EN 10204-2004: 3.1 for Stabilized, Copper-Modified Austenitic Stainless Steel Fasteners (ASTM A194 Grade 8CLNCuB). Verify chemical compositions, specialized heat treatments, and mechanical performance parameters certified for high-pressure/temperature service.
This sample mill test certificate reflects the thorough quality verification package standard for stabilized, copper-modified austenitic stainless steel heavy hex nuts shipped for severe service environments.
Review the standard parameters and layout before downloading the full document.
TC Number
S62/26-XX
TC Date
23.06.20XX
Material Spec
ASTM A194 Grade 8CLNCuB
Shape / Size
Hex Nut / M24
Dimensions / Item
Heavy Hex Nut M24-3.0P
Quantity
400.00 NOS
| C | Mn | P | S | Si | Cr | Ni | Nb | Cu |
|---|---|---|---|---|---|---|---|---|
| 0.05 | 1.50 | 0.030 | 0.015 | 0.50 | 17.50 | 10.50 | 0.40 | 0.80 |
| Max: 0.08 | Max: 2.00 | Max: 0.045 | Max: 0.030 | Max: 1.00 | Min: 17.00 Max: 19.00 |
Min: 10.00 Max: 13.00 |
Min: 0.10 Max: 0.80 |
Min: 0.50 Max: 1.50 |
| TENSILE STRENGTH (Mpa) | YIELD STRENGTH 0.2% Offset (Mpa) | % ELONGATION (GL-50mm) | HARDNESS (HRC) |
|---|---|---|---|
| 650.00 | 350.00 | 35.00 | 25, 26, 24 |
| Min: 550 | Min: 240 | Min: 30 | Max: 32 |
Our MTC certificates map to the demanding industrial standards for fasteners. The test reports confirm compliance with As Per ASME/ASTM A194 Grade 8CLNCuB with respect to the tests carried out.
| Standard / Requirement | Confirmation on Certificate |
|---|---|
| Visual Inspection | 100% visual inspection carried out & found free from defects. |
| Safety Requirements | Material is free from radioactive contamination. |
| Weld Repairs | No weld repair Perform. |
| Dimensional Accuracy | All Dimensions are as per PO Specification. |
We confirm that above mentioned Items was Manufactured, Sampled, Tested and Inspected in accordance with the subjected Customer's Purchase Order and as applicable Drawings, Material Specifications, Codes & Standards and the results of the items have been determined to meet the users' requirements.
The stabilization provided by Niobium/Columbium prevents the formation of harmful chromium carbides at grain boundaries. This stabilization, combined with copper modification for improved surface characteristics, allows the material to maintain its integrity and corrosion resistance even when exposed to high-temperature service environments where sensitization might otherwise occur.
The MTC logs a Solution Annealing phase followed by a rapid Water Quench. This process dissolves any chromium carbides and keeps the alloying elements, including the stabilizing Niobium and Copper, uniformly distributed within the austenitic structure to ensure peak corrosion and oxidation resistance.
Yes, the document strictly states that the material is free from radioactive contamination and undergoes a 100% visual inspection to ensure it is free from manufacturing defects.