Access a comprehensive, professionally formatted Material Test Certificate according to EN 10204-2004: 3.1 for UNS C11000 (Electrolytic Tough Pitch Copper) fasteners. Review the documentation verifying its 99.9% minimum purity, guaranteed electrical conductivity for power transmission, and cold-worked mechanical strength.
This sample mill test certificate details the specific physical and mechanical testing parameters required for high-conductivity copper fasteners manufactured to ASTM F468 specifications, commonly used in electrical busbars, switchgears, and grounding systems.
Review the specialized nonferrous parameters and electrical conductivity layout before downloading.
TC Number
S182/26-XX
TC Date
08.06.20XX
Material Spec
ASTM F468 UNS C11000 (ETP)
Bar Shape / Size
Hexagon Bar / 16 mm
Dimensions / Item
Hex Head Bolt M10-1.5P x 40 mm
Quantity
500.00 NOS
| Cu (incl. Ag) | O (Oxygen) | Bi | Pb | Fe |
|---|---|---|---|---|
| 99.95 | 0.030 | 0.0005 | 0.002 | 0.001 |
| Min: 99.90 | Typical: 0.02 - 0.04 | Trace | Trace | Trace |
| TENSILE STRENGTH (MPa) | YIELD STRENGTH 0.5% Ext (MPa) | % ELONGATION (GL-50mm) | HARDNESS (HRF) | ELECTRICAL COND. (% IACS) |
|---|---|---|---|---|
| 325.40 | 260.20 | 18.50 | 85, 87, 86 | 101.2 |
| Min: 310 (45 ksi) | Min: 240 (35 ksi) | Min: 12 | Min: 80 | Min: 100.0 |
Our MTC certificates for nonferrous fasteners align with the stringent requirements of the electrical generation, transmission, and marine industries. The test reports confirm exact compliance with ASTM F468 with respect to the specific heat and lot tested.
| Standard / Requirement | Confirmation on Certificate |
|---|---|
| Visual Inspection | 100% visual inspection carried out & found free from defects. |
| Conductivity Standard | Tested via ASTM B193. Meets 100% minimum International Annealed Copper Standard (IACS). |
| Magnetic Permeability | Material is confirmed Non-Magnetic. |
| Dimensional Accuracy | All Dimensions are as per PO Specification / ASME B18.2.1. |
We confirm that the above mentioned items were Manufactured, Sampled, Tested, and Inspected in accordance with the subjected Customer's Purchase Order and applicable Drawings, Material Specifications, Codes & Standards.
ETP stands for Electrolytic Tough Pitch. It is the most common and widely used copper grade for electrical applications. It is refined electrolytically to a minimum of 99.90% purity, intentionally leaving a tiny amount of oxygen (typically 0.02% to 0.04%) which improves its castability and conductivity by tying up trace impurities.
Copper fasteners are rarely chosen primarily for mechanical strength; they are chosen because they must act as conductive bridges in high-current electrical busbars, switchgears, and grounding grids. Logging the % IACS (International Annealed Copper Standard) guarantees the engineer that the fastener will not create a high-resistance bottleneck that could cause overheating in the circuit.
Welding or high-temperature brazing of C11000 is not recommended. Because ETP copper contains residual oxygen, exposing it to hydrogen gas at high temperatures (as found in welding flames) can cause the hydrogen to react with the oxygen, forming steam pockets inside the metal. This leads to "hydrogen embrittlement" and cracking. If welding is required, Oxygen-Free Copper (OFHC, UNS C10200) should be specified instead.