Access a comprehensive, professionally formatted Material Test Certificate according to EN 10204-2004: 3.1 for Hastelloy C2000 (ASTM F468 UNS N06200). Inspect the exact documentation your QA and engineering teams will receive with every Ananka Fasteners order.
This sample mill test certificate mirrors the rigorous QA documentation package shipped with every high-performance order from Ananka Fasteners Pvt Ltd.
Review the standard parameters and layout before downloading the full document.
TC Number
S35/26-27
TC Date
13.06.2026
Material Spec
ASTM F468 UNS N06200-2023
Bar Shape / Size
Round Bar / 16 mm
Dimensions / Item
Hex Head Bolt M16-2P x 75 mm
Quantity
10.00 NOS
| C | Mn | P | S | Si | Cr | Mo | Fe | Al | Cu | Co | Ni |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.006 | 0.23 | 0.012 | 0.003 | 0.31 | 23.17 | 15.54 | 1.86 | 0.12 | 1.52 | 0.98 | Rem |
| Max: 0.010 | Max: 0.50 | Max: 0.025 | Max: 0.010 | Max: 0.80 | Min: 22.00 Max: 24.00 |
Min: 15.00 Max: 17.00 |
Max: 3.00 | Max: 0.50 | Min: 1.30 Max: 1.90 |
Max: 2.00 | - |
| TENSILE STRENGTH (Mpa) | YIELD STRENGTH 0.2% Offset (Mpa) | % ELONGATION (GL-50mm) | HARDNESS (HRB) |
|---|---|---|---|
| 805.17 | 416.67 | 54.76 | 87, 89, 90 |
| Min: 690 | Min: 310 | Min: 45 | Max: 100 |
Our MTC certificates map to the demanding industrial standards for fasteners. The test reports confirm compliance with As Per ASME/ASTM F468 UNS N06200 EDT. 2023 with respect to the tests carried out.
| Standard / Requirement | Confirmation on Certificate |
|---|---|
| Visual Inspection | 100% visual inspection carried out & found free from defects. |
| Safety Requirements | Material is free from radioactive contamination. |
| Weld Repairs | No weld repair Perform. |
| Dimensional Accuracy | All Dimensions are as per PO Specification. |
We confirm that above mentioned Items was Manufactured, Sampled, Tested and Inspected in accordance with the subjected Customer's Purchase Order and as applicable Drawings, Material Specifications, Codes & Standards and the results of the items have been determined to meet the users' requirements.
The MTC specifically logs a Solution Annealing Process, followed by a Water Quench.
The MTC verifies that Chemical, Mechanical & hardness tests are carried out at room temperature 25°C.
Yes, the document strictly states that the material is free from radioactive contamination and undergoes a 100% visual inspection to ensure it is free from defects.